In this work, the scanning vibrating electrode technique (SVET) and the quartz crystal microbalance technique (EQCM) were used to characterize the electrochemical interaction
of two corrosion inhibitors, 2-Mercaptobenzothiazole and 3-Amino-1,2,4-triazole (ATA), in Au and Cu samples individually and with both metals connected in order to form a galvanic pair Au-Cu