Mostrar el registro sencillo del ítem
Use of amperometric and potentiometric probes in scanning electrochemical microscopy for the spatially-resolved monitoring of severe localized corrosion sites on aluminum alloy 2098-T351
dc.contributor.author | Souto, Ricardo Manuel | |
dc.contributor.author | Da Silva, Rejane Maria P. | |
dc.contributor.author | Izquierdo Pérez, Javier | |
dc.contributor.author | Milagre, Mariana X. | |
dc.contributor.author | Betancor-Abreu, A. | |
dc.contributor.author | Costa, Isolda | |
dc.contributor.other | Química | |
dc.contributor.other | Proyecto CTQ2018-80522-P Grupo de Electroquímica y Corrosión, Instituto de Materiales y Nanotecnología | |
dc.date.accessioned | 2021-02-15T14:05:23Z | |
dc.date.available | 2021-02-15T14:05:23Z | |
dc.date.issued | 2021 | |
dc.identifier.uri | http://riull.ull.es/xmlui/handle/915/22284 | |
dc.description.abstract | Amperometric and potentiometric probes were employed for the detection and characterization of reactive sites on the 2098-T351 Al-alloy (AA2098-T351) using scanning electrochemical microscopy (SECM). Firstly, the probe of concept was performed on a model Mg-Al galvanic pair system using SECM in the amperometric and potentiometric operation modes, in order to address the responsiveness of the probes for the characterization of this galvanic pair system. Next, these sensing probes were employed to characterize the 2098-T351 alloy surface immersed in a saline aqueous solution at ambient temperature. The distribution of reactive sites and the local pH changes associated with severe localized corrosion (SLC) on the alloy surface were imaged and subsequently studied. Higher hydrogen evolution, lower oxygen depletion and acidification occurred at the SLC sites developed on the 2098-T351 Al-alloy | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | en | |
dc.relation.ispartofseries | Sensors, 21 (2021) 1132 | |
dc.rights | Licencia Creative Commons (Reconocimiento-No comercial-Sin obras derivadas 4.0 Internacional) | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es_ES | |
dc.title | Use of amperometric and potentiometric probes in scanning electrochemical microscopy for the spatially-resolved monitoring of severe localized corrosion sites on aluminum alloy 2098-T351 | en |
dc.type | info:eu-repo/semantics/article | |
dc.identifier.doi | 10.3390/s21041132 | |
dc.subject.keyword | scanning electrochemical microscopy | en |
dc.subject.keyword | amperometric and potentiometric probes | en |
dc.subject.keyword | aluminum alloy 2098-T351 | en |
dc.subject.keyword | severe localized corrosion | en |
dc.subject.keyword | Mg-Al galvanic pair | en |