Mostrar el registro sencillo del ítem

dc.contributor.authorSouto, Ricardo Manuel 
dc.contributor.authorFilotás, Dániel
dc.contributor.authorIzquierdo Pérez, Javier 
dc.contributor.authorFernández Pérez, Bibiana María 
dc.contributor.authorNagy, Lívia
dc.contributor.authorNagy, Géza
dc.contributor.otherQuímica
dc.contributor.otherGrupo de Electroquímica y Corrosión Departamento de Química Instituto de Materiales y Nanotecnología
dc.date.accessioned2022-04-06T13:55:13Z
dc.date.available2022-04-06T13:55:13Z
dc.date.issued2022
dc.identifier.urihttp://riull.ull.es/xmlui/handle/915/26909
dc.description.abstractSpatially resolved information on corrosion reactions operating at the cut edges of coated metals can be obtained using microelectrochemical scanning techniques using a suitable selection of operation modes and scanning probes. The scanning vibrating electrode technique (SVET) provides current density maps with a spatial resolution of the order of the dimensions of the sample, which allows the temporal evolution of the corrosion reactions to be followed over time. This leads to the identification and localization of cathodic and anodic sites, although the technique lacks chemical specificity for the unequivocal identification of the reactive species. The application of scanning electrochemical microscopy (SECM) was previously limited to image cathodic reaction sites, either due to oxygen consumption in the amperometric operation or by the alkalinisation of the electrolyte in potentiometric operation. However, it is shown that anodic sites can be effectively monitored using an ion-selective microelectrode (ISME) as a probe. The ISME probes detected differences in the local concentrations of Zn2+ and OH− ions from the cut edges of a complete coil coating system compared to the same system after the polymeric layers were removed. In this way, it has been shown that the inhibitor loading in the polymer layers effectively contributes to reducing the corrosion rates at the cut edge, thus helping to extend the useful life of the sacrificial galvanized layer bonded directly to the steel matrix. Additionally, these two probe configurations can be integrated into a multi-electrode tip for potentiometric operation to simultaneously monitor localized changes in pH values and metal ion dissolution in a single scan. Spatial and temporal distributions were further investigated using different rastering procedures, and the potential of constructing pseudomaps for 2D-imaging is described.en
dc.format.mimetypeapplication/pdf
dc.language.isoen
dc.relation.ispartofseriesMolecules, 27 (2022) 2167
dc.rightsLicencia Creative Commons (Reconocimiento-No comercial-Sin obras derivadas 4.0 Internacional)
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es_ES
dc.titleContributions of microelectrochemical scanning techniques for the efficient detection of localized corrosion processes at the cut edges of polymer-coated galvanized steel. D. Filotás, J. Izquierdo, B.M. Fernández-Pérez, L. Nagy, G. Nagy, R.M. Souto.en
dc.typeinfo:eu-repo/semantics/article
dc.identifier.doi10.3990/molecules27072167


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Licencia Creative Commons (Reconocimiento-No comercial-Sin obras derivadas 4.0 Internacional)
Excepto si se señala otra cosa, la licencia del ítem se describe como Licencia Creative Commons (Reconocimiento-No comercial-Sin obras derivadas 4.0 Internacional)