Ecografía ocular frente a catéter intraparenquimatoso en la monitorización de la presión intracraneana. Unidad de cuidados intensivos del Complejo Hospitalario Universitario de Canarias
dc.contributor.advisor | Marrero González, Cristo Manuel | |
dc.contributor.author | Bautista Molina, Alejandro | |
dc.contributor.other | Grado En Enfermería | |
dc.date.accessioned | 2022-07-08T11:19:42Z | |
dc.date.available | 2022-07-08T11:19:42Z | |
dc.date.issued | 2022 | |
dc.identifier.uri | http://riull.ull.es/xmlui/handle/915/28856 | |
dc.description.abstract | El contenido craneano está formado por tejido nervioso, sangre y líquido cefalorraquídeo, dichos componentes conforman el volumen intracraneano, este volumen se rige por la ley de MonroKellie, debido a esta ley, la presión intracraneal se considera una constante y su equilibrio es fundamental para el correcto funcionamiento de las células nerviosas. La ecografía ocular es un método no invasivo, innovador y eficaz que permitirá a los enfermeros medir la presión intracraneal de una manera sencilla y rápida, pudiendo lograr una sensibilidad del 100%, una especificidad del 89.2% a la hora de detectar una PIC elevada, además de un valor predictivo positivo de hasta 83.3% y un valor predictivo negativo de 100%. Por tanto, este proyecto plantea un nuevo estudio comparando el catéter intraparenquimatoso con la ecografía ocular, y así comprobar su potencial. | es |
dc.description.abstract | The cranial content is made up of nervous tissue, blood and cerebrospinal fluid, these components make up the intracranial volume, this volume is governed by the Monro-Kellie law, due to this law, intracranial pressure is considered a constant and its balance is fundamental for the proper functioning of nerve cells. Ocular ultrasound is a non-invasive, innovative and effective method that will allow nurses to measure intracranial pressure in a simple and fast way, being able to achieve a sensitivity of 100%, a specificity of 89.2% when detecting elevated ICP, in addition to a positive predictive value of up to 83.3% and a negative predictive value of 100%. Therefore, this project proposes a new study comparing the intraparenchymal catheter with ocular ultrasound, and thus verify its effectiveness. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | es | |
dc.rights | Licencia Creative Commons (Reconocimiento-No comercial-Sin obras derivadas 4.0 Internacional) | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es_ES | |
dc.title | Ecografía ocular frente a catéter intraparenquimatoso en la monitorización de la presión intracraneana. Unidad de cuidados intensivos del Complejo Hospitalario Universitario de Canarias | |
dc.type | info:eu-repo/semantics/bachelorThesis | |
dc.subject.keyword | Presión intracraneal | |
dc.subject.keyword | Ecografía ocular | |
dc.subject.keyword | Catéter intraparenquimatoso | |
dc.subject.keyword | Enfermeros |