dc.description.abstractEn la actualidad, el sector de la radiof´ısica est´a creciendo en Espa˜na, gracias a las inversiones que est´an haciendo los hospitales p´ublicos en equipos para tratamientos como la radioterapia. En concreto, el Hospital Universitario de Canarias (HUC) ha adquirido el equipo ioRT-50 (Intraoperative radiation therapy - 50 keV) que puso en marcha en 2019 para realizar t´ecnicas de radioterapia superficial y radioterapia intraoperatoria. El equipo consiste en un brazo articulado que sostiene un tubo de rayos X de baja energ´ıa, un dep´osito de agua y un conjunto de aplicadores, que permite impartir tratamientos de radioterapia. Estos aplicadores emiten una distribuci´on de radiaci´on caracter´ıstica, y para medirla se utiliza una c´amara de ionizaci´on y pel´ıculas radiocr´omicas. Se trabaja con un voltaje pico de 70 kV y tiempos de disparo de 1 y 2 minutos. El par´ametro que se mide es la dosis [Gy] y se relaciona con la profundidad [mm]. Se realiza la verificaci´on anual de los aplicadores y se dise˜na un nuevo m´etodo de medida para su comprobaci´on, el cual se ha incorporado en el Hospital Universitario. Adem´as los datos obtenidos se incluir´an en la base de datos del sistema del Hospital.es
dc.description.abstractCurrently, the radiophysics sector is growing in Spain, thanks to the investments that public hospitals are making in equipment for treatments such as radiotherapy. Specifically, the University Hospital of Canary Islands (HUC) has acquired the ioRT-50 (Intraoperative radiation therapy - 50 keV) equipment, launched in 2019, to perform superficial radiotherapy and intraoperative radiotherapy techniques. The equipment consists of an articulated arm that holds a low-energy X-ray tube, a water tank and a set of applicators, which allows imparting treatments of radiotherapy. These applicators emit a characteristic radiation distribution. To measure it, an ionization chamber and radiochromic films are used. It works with a peak voltage of 70 kV and shooting times of 1 and 2 minutes. The parameter that is measured is the dose [Gy] and it is related to the depth [mm]. The annual verification of the applicators is carried out and a new method of measure has been designed, which has been incorporated into the University Hospital. In addition, the data obtained will be included in the database of the Hospital system.en
dc.format.mimetypeapplication/pdf
dc.language.isoes
dc.rightsLicencia Creative Commons (Reconocimiento-No comercial-Sin obras derivadas 4.0 Internacional)
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/deed.es_ES
dc.titleVerificación anual de un conjunto de aplicadores utilizados para radioterapia intraoperatoria en el HUC
dc.typeinfo:eu-repo/semantics/bachelorThesis