Increasing SARS-CoV-2 RT-qPCR testing capacity by sample pooling.
Fecha
2020Resumen
Objectives: Limited testing capacity has characterized the ongoing COVID-19
pandemic in Spain, hampering a timely control of outbreaks and the possibilities to
reduce the escalation of community transmissions. Here we investigated the potential of
using pooling of samples followed by one-step retrotranscription and quantitative PCR
(RT-qPCR) to increase SARS-CoV-2 testing capacity.
Methods: We first evaluated different sample pooling (1:5, 1:10 and 1:15) prior to RNA
extractions followed by standard RT-qPCR for SARS-CoV-2/COVID-19 diagnosis.
The pool size achieving reproducible results in independent tests was then used for
assessing nasopharyngeal samples in a tertiary hospital during August 2020.
Results: We found that pool size of five samples achieved the highest sensitivity
compared to pool sizes of 10 and 15, showing a mean (± SD) Ct shift of 3.5 ± 2.2
between the pooled test and positive samples in the pool. We then used a pool size of
five to test a total of 895 pools (4,475 prospective samples) using two different RTqPCR kits available at that time. The Real Accurate Quadruplex corona-plus PCR Kit
(PathoFinder) reported the lowest mean Ct (± SD) shift (2.2 ± 2.4) among the pool and
the individual samples. The strategy allows detecting individual samples in the positive
pools with Cts in the range of 16.7-39.4.
Conclusions: We found that pools of five samples combined with RT-qPCR solutions
helped to increase SARS-CoV-2 testing capacity with minimal loss of sensitivity
compared to that resulting from testing the samples independently.