Oxidized multi-walled carbon nanotubes for the dispersive solid-phase extraction of quinolone antibiotics from water samples using capillary electrophoresis and large volume sample stacking with polarity switching
Date
2011Abstract
In this work, a new method for the determination of eleven quinolone antibiotics
(moxifloxacin, lomefloxacin, danofloxacin, ciprofloxacin, levofloxacin, marbofloxacin, enrofloxacin, difloxacin, pefloxacin, oxolinic acid and flumequine) in different water samples using dispersive solid-phase extraction (dSPE) and capillary zone
electrophoresis with diode-array detection was developed. Oxidized multi-walled
carbon nanotubes (o-MWCNTs) were used for the first time as stationary phases for the
off-line preconcentration by dSPE of the antibiotics. A 65 mM phosphate buffer at pH
8.5 was found adequate for analyte separation while large volume sample stacking with
polarity switching of the analytes dissolved in water containing 10% v/v of acetonitrile
was carried out in order to improve the sensitivity. dSPE parameters, such as sample
volume and pH, o-MWCNTs amount, volume and type of eluent in dSPE were optimized. Application of the developed method to the analysis of spiked Milli-Q,
mineral, tap, and wastewater samples resulted in good recoveries values ranging from
62.3 to 116% with relative standard deviation values lower than 7.7% in all cases.
Limits of detection were in the range of 28-94 ng/L. The proposed method is very fast,
simple, repeatable, accurate and highly selective.