RT info:eu-repo/semantics/article T1 Multi-barrel electrodes containing an internal micro-reference for the improved visualization of the galvanic corrosion of magnesium using potentiometric SECM A1 Souto, Ricardo Manuel A1 Filotás, Dániel A1 Fernández Pérez, Bibiana María A1 Nagy, Lívia A1 Nagy, Géza K1 SECM K1 ion selective microelectrode K1 galvanic corrosion K1 pH distribution K1 Mg dissolution K1 magnesium AB Simultaneous monitoring of pH and Mg2+ distributions above AZ63 magnesium alloy, eitherspontaneously corroding or galvanically coupled with iron, was achieved using SECM in thepotentiometric operation. By introducing an internal micro-reference electrode in a multi-barrelarrangement of the ion-selective microelectrode used as scanning probe, superior performancewas achieved compared to conventional single-barrel and double-barrel assemblies. In this way,the impact of the overestimated acidification accompanying metal dissolution using conventionaltips was established from model experiments using non ion-sensitive open micropipettes and pHantimony microelectrodes. It is shown that the simultaneously acquired pH and pMg mapsprovide complementary information on the spontaneous and galvanic corrosion of AZ63magnesium alloy YR 2019 FD 2019 LK http://riull.ull.es/xmlui/handle/915/18948 UL http://riull.ull.es/xmlui/handle/915/18948 LA en DS Repositorio institucional de la Universidad de La Laguna RD 22-nov-2024