RT info:eu-repo/semantics/article T1 Spatially resolved measurement of electrochemical activity and pH distributions in corrosion processes by scanning electrochemical microscopy using antimony microelectrode tips A1 Souto, Ricardo Manuel A1 Izquierdo Pérez, Javier A1 Nagy, Lívia A1 Varga, Ágnes A1 Santana, Juan José A1 Nagy, Géza K1 Scanning electrochemical microscopy K1 galvanic corrosion K1 pH distribution K1 antimony microelectrode AB A new method for the spatially-resolved measurement of pH during corrosion processes with the scanning electrochemical microscope (SECM) is presented. Antimony tips are employed because the dual-function characteristics of this material allow the combined amperometric/potentiometric operation of the SECM. The applicability of this technique is illustrated by considering the galvanic corrosion of a model zinc-iron pair immersed in 0.1 M NaCl aqueous solution. Spatially resolved images of pH and oxygen concentration above the metal specimens could be obtained in the same experiment. YR 2011 FD 2011 LK http://riull.ull.es/xmlui/handle/915/19139 UL http://riull.ull.es/xmlui/handle/915/19139 LA en DS Repositorio institucional de la Universidad de La Laguna RD 27-dic-2024