RT info:eu-repo/semantics/article T1 Use of amperometric and potentiometric probes in scanning electrochemical microscopy for the spatially-resolved monitoring of severe localized corrosion sites on aluminum alloy 2098-T351 A1 Souto, Ricardo Manuel A1 Da Silva, Rejane Maria P. A1 Izquierdo Pérez, Javier A1 Milagre, Mariana X. A1 Betancor-Abreu, A. A1 Costa, Isolda A2 Química A2 Proyecto CTQ2018-80522-P Grupo de Electroquímica y CorrosiónInstituto de Materiales y Nanotecnología K1 scanning electrochemical microscopy K1 amperometric and potentiometric probes K1 aluminum alloy 2098-T351 K1 severe localized corrosion K1 Mg-Al galvanic pair AB Amperometric and potentiometric probes were employed for the detection and characterizationof reactive sites on the 2098-T351 Al-alloy (AA2098-T351) using scanning electrochemicalmicroscopy (SECM). Firstly, the probe of concept was performed on a model Mg-Al galvanic pairsystem using SECM in the amperometric and potentiometric operation modes, in order to addressthe responsiveness of the probes for the characterization of this galvanic pair system. Next, thesesensing probes were employed to characterize the 2098-T351 alloy surface immersed in a salineaqueous solution at ambient temperature. The distribution of reactive sites and the local pH changesassociated with severe localized corrosion (SLC) on the alloy surface were imaged and subsequentlystudied. Higher hydrogen evolution, lower oxygen depletion and acidification occurred at the SLCsites developed on the 2098-T351 Al-alloy YR 2021 FD 2021 LK http://riull.ull.es/xmlui/handle/915/22284 UL http://riull.ull.es/xmlui/handle/915/22284 LA en DS Repositorio institucional de la Universidad de La Laguna RD 24-nov-2024