Mostrar el registro sencillo del ítem
Validación de la metodología para la determinación analítica de ácidos grasos en sangre humana
dc.contributor.advisor | Pérez Pérez, José Antonio | |
dc.contributor.advisor | Díaz Gómez, N. Marta | |
dc.contributor.author | Santana Ramos, Jose Domingo | |
dc.contributor.other | Grado En Biología | |
dc.date.accessioned | 2022-06-28T12:28:59Z | |
dc.date.available | 2022-06-28T12:28:59Z | |
dc.date.issued | 2022 | |
dc.identifier.uri | http://riull.ull.es/xmlui/handle/915/28469 | |
dc.description.abstract | En la sanidad es de elevada relevancia establecer buscar métodos analíticos fiables para determinar los perfiles de ácidos grasos en sangre de forma más rápida que los métodos convencionales. Por todo ello, han surgido nuevos métodos que intentan lograr los mismos resultados con metodologías no invasivas y más reducidas en personal y costes. Uno de estos novedosos métodos es el análisis a través de una transmetilación directa, mediante el uso de discos de papel de filtro, en los que se depositan gotas de sangre obtenidas por punción con lancetas en la yema de los dedos. En este estudio, se intenta validar este método analizando los perfiles de ácidos grasos de muestras de sangre que se compararán con otros obtenidos por transmetilación directa sin filtro y transmetilación indirecta. Además, como procedimiento adicional, se comprobará el estado de conservación de las muestras tras una semana de almacenamiento en nevera en presencia de butilhidroxitolueno (BHT) como agente antioxidante. Los resultados obtenidos en el estudio respaldan la viabilidad de este método en la determinación de perfiles de ácidos grasos en una gota de sangre, al no encontrar diferencias significativas con los otros métodos utilizados. También quedó comprobado el buen estado de las muestras tras la conservación con BHT. | es |
dc.description.abstract | In healthcare, it is highly relevant to establish reliable analytical methods to determine blood fatty acid profiles faster than conventional methods. Therefore, new methods have emerged that attempt to achieve the same results with non-invasive methodologies and reduced personnel and costs. One of these new methods is the analysis through direct transmethylation, using filter paper discs on which blood drops obtained by lancet puncture are deposited on the fingertips. In this study, the aim is to validate this method by analysing the fatty acid profiles of blood samples which will be compared with those obtained by direct transmethylation without filter and indirect transmethylation. In addition, as a further procedure, the shelf life of the samples will be tested after one week of storage in refrigeration in the presence of butylated hydroxytoluene (BHT) as antioxidant agent. The results obtained in the study support the feasibility of this method for the determination of fatty acid profiles in a drop of blood, as no significant differences were found with the other methods used. The good condition of the samples after preservation with BHT was also verified. | en |
dc.format.mimetype | application/pdf | |
dc.language.iso | es | |
dc.rights | Licencia Creative Commons (Reconocimiento-No comercial-Sin obras derivadas 4.0 Internacional) | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/deed.es_ES | |
dc.subject | Ácidos grasos; Sangre; Transmetilación directa; Yema del dedo; Butilhidroxitolueno (BHT) | |
dc.title | Validación de la metodología para la determinación analítica de ácidos grasos en sangre humana | |
dc.type | info:eu-repo/semantics/bachelorThesis | |
dc.subject.keyword | Ácidos grasos | |
dc.subject.keyword | Sangre | |
dc.subject.keyword | Transmetilación directa | |
dc.subject.keyword | Yema del dedo | |
dc.subject.keyword | Butilhidroxitolueno (BHT) |