RT info:eu-repo/semantics/article T1 Novel dual microelectrode probe for the simultaneous visualization of local Zn2+ and pH distributions in galvanic corrosion processes A1 Souto, Ricardo Manuel A1 Filotás, Dániel A1 Fernández Pérez, Bibiana María A1 Izquierdo Pérez, Javier A1 Nagy, Lívia A1 Nagy, Géza K1 Iron K1 Zinc K1 Scanning electrochemical microscopy K1 Ion selective microelectrode K1 Galvanic corrosion K1 Local pH distribution AB Novel dual potentiometric microsensor probe has been developed for the simultaneous detection of Zn2+ concentration and pH distributions in the Scanning Electrochemical Microscopy investigation of corroding galvanized steel. The individual sensors show nearly theoretical behavior over a wide concentration range. The applicability of this probe is first demonstrated on a Fe-Zn galvanic couple, as it shows excellent performance in these simultaneous model experiments. In addition, linear scans recorded over a cut edge of coated galvanized steel evidences the complementary information gathered on the electrochemical behavior of the corroding sample, and adumbrates promising and feasible applications of multi-barrel microelectrodes in corrosion research. YR 2017 FD 2017 LK http://riull.ull.es/xmlui/handle/915/19013 UL http://riull.ull.es/xmlui/handle/915/19013 LA en DS Repositorio institucional de la Universidad de La Laguna RD 21-may-2024